MRU MGAprime – high end flue gas emission analyzer for emission monitoring of various industrial sites. High resolution 7″ color display with graphical output of the measured values. All-metal housing with soft bumper corners for the harsh industrial everyday use. Operation via smartphone or PC via VNC connection, mirrored device display on smartphone.
Specifications
- Nitric monoxideYes
- Measuring range0 ppm ... 200 / 4 000 ppm
- Resolution0.1 ppm
- Repeatability2 ppm or 1 % reading
- Nitric dioxideYes
- Measuring range0 ppm ... 300 / 1 000 ppm
- Resolution0.1 ppm
- Repeatability5 ppm or 1 % reading
- Sulfur dioxideYes
- Measuring range0 ppm ... 300 / 4 000 ppm
- Resolution0.1 ppm
- Repeatability5 ppm or 1 % reading
- Carbon dioxideYes
- Measuring range0 % ... 50 %
- Resolution0.01 %
- Repeatability0.2 % or 1 % reading
- Carbon monoxideYes
- Measuring range0 ppm ... 175 / 10 000 ppm
- Resolution0.1 ppm
- Repeatability2 ppm or 1 % reading
- Nitrous oxideYes
- Measuring range0 ppm ... 100 / 500 ppm
- Resolution0.1 ppm
- Repeatability2 ppm or 1 % reading
- MethaneYes
- Measuring range0 ppm ... 500 / 10 000 ppm
- Resolution0.1 ppm
- Repeatability10 ppm or 1 % reading
- PropaneYes
- Measuring range0 ppm ... 200 / 5 000 ppm
- Resolution0.1 ppm
- Repeatability2 ppm or 1 % reading
- Oxygen (EC)Yes
- Measuring range0 % ... 25 %
- Resolution0.01 %
- Accuracy0.20 % absolute
- Oxygen (PM)Yes
- Measuring range0 % ... 25 %
- Resolution0.01 %
- Accuracy0.1 %
- HydrogenYes
- Measuring range0 ppm ... 1 000 / 2 000 ppm
- Resolution1 ppm
- Accuracy± 5 ppm or 5 % (0 ppm ...500 ppm), 10 % (>500 ppm) of reading
- Hydrogen (high)Yes
- Measuring range0 ppm ... 10,000 / 20,000 ppm
- Resolution10 ppm
- Accuracy± 200 ppm or 5 % (0 ppm ... 10 000 ppm), 10 % (>10 000 ppm) of reading
- Stack gas temperatureYes
- Measuring range0 °C ... 1 100 °C
- Resolution1 °C
- Accuracy±2 °C or 2 % reading
- Combustion air temperatureYes
- Measuring range0 °C ... 100 °C
- Resolution1 °C
- Accuracy±1 °C or 1 % reading
- Flow velocity measurementYes
- Measuring range-120 hPa ... +120 hPa
- Resolution1 Pa
- Accuracy±2 Pa or 1 % reading
- Hydrogen (high)Yes
- Measuring range3 m/s ... 100 m/s
- Resolution0.1 m/s
- Accuracy±1 m/s or 1 % reading
- Combustion calculationsLosses, Air Ratio, dew point, CO2
- Operating systemLinux
- Display7" TFT (800 x 480 px) colour touch screen, backlit
- Memoryinternal 10 000 data sets, external USB stick
- InterfacesRS-485, RJ45 (Ethernet), Wi-Fi, Bluetooth
- Printerexternal USB / Wi-Fi printer
- Analog output / input4 mA ... 20 mA
- Universal analog input (AUX)0 V ... 10 V DC, 4 mA ... 20 mA, NiCrNi-thermocouple, RS-485
- BatteryLi-ion
- Mains free operation timefor standby 1 hour
- Operating temperature+5 °C ... +45 °C
- Power supply86 V ... 265 V AC, 47 Hz ... 63 Hz
- Protection classIP20 (or IP42 inside transport case)
- Dimensions430 x 290 x 150 mm
- Weightapprox. 10 kg device only, approx. 10 kg per bag (1x device and 1x accessories)
Accessories
No results found.